Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 508
Filtrar
1.
Integr Zool ; 2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38556643

RESUMO

The tree frog is a prominent amphibian among terrestrial vertebrates known for its ability to adhere to various surfaces through the capillary forces of water in the microchannels between micropillars on its disc-shaped toe pads, a phenomenon known as wet adhesion. However, the secretion pattern of mucus on the attachment surface of living tree frog toe pads and the distribution of active mucus pores (AMPs) have not yet been fully elucidated. In this study, we utilized synchrotron X-ray micro-computed tomography and interference reflection microscopy to obtain the spatial distribution of the entire population of ventral mucus glands on the toe pads of living tree frogs and the real-time mucus secretion patterns from the ventral mucus pores on the contact surface under different environmental conditions. We observed that the number and secretion frequency of AMPs on the toe pad are regulated according to environmental conditions. Such dynamic mucus secretion on the tree frog's toe pad could contribute to the understanding of capillary force regulation for wet adhesion and the development of adhesive surfaces by mimicking the mucus-secreting toe pad.

2.
Dent Res J (Isfahan) ; 21: 12, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38476716

RESUMO

Background: This study aimed to compare the apical transportation and centering ability of One Curve, HyFlex EDM, and EdgeFile X1 in curved mesiobuccal and mesiolingual canals of mandibular first molars. Materials and Methods: In this in vitro experimental study, 60 mesiobuccal and mesiolingual canals of the mandibular first molars with a minimum length of 19 mm and 25°-40° curvature were randomly divided into three groups (n = 20) for root canal preparation with One Curve, HyFlex EDM, and EdgeFile X1. After access cavity preparation and confirming the glide path, the baseline micro-computed tomography (micro-CT) scans were obtained, and the root canals were instrumented with the respective systems according to the manufacturers' instructions. Apical transportation and centering ability were assessed at 1, 3, 5, and 7 mm from the apex by comparing pre- and postinstrumentation micro-CT scans. One-way ANOVA, independent t-test, and Duncan's post hoc test were used to statistically compare the groups, and data were analyzed by SPSS version 24 (alpha = 0.05). Results: The three groups were not significantly different regarding apical transportation at 5 and 7 mm from the apex (P > 0.05). At 1 mm level, One Curve caused significantly lower apical transportation; while, at 3 mm level, HyFlex EDM resulted in significantly higher apical transportation (P < 0.05). No significant difference was noted in the centering ability of the three groups at 1, 3, and 5 mm from the apex (P > 0.05). At 7 mm level, EdgeFile X1 showed significantly lower centering ability (P < 0.05). Conclusion: One Curve caused lower canal transportation in the apical third compared with EdgeFile and HyFlex EDM, but no significant difference was noted among the three in the coronal third of the roots.

3.
Environ Sci Technol ; 58(8): 3747-3754, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38302413

RESUMO

Basalt formations are promising candidates for the geologic storage of anthropogenic CO2 due to their storage capacity, porosity, permeability, and reactive geochemical trapping ability. The Wallula Basalt Carbon Storage Pilot Project demonstrated that supercritical CO2 injected into >800 m deep Columbia River Basalt Group stacked reservoir flow tops mineralizes to ankerite-siderite-aragonite on month-year time scales, with 60% of the 977 metric tons of CO2 converted within 2 years. The potential impacts of mineral precipitation and consequent changes in the rock porosity, pore structure, pore size, and pore size distributions have likely been underestimated hitherto. Herein, we address these knowledge gaps using X-ray microcomputed tomography (XMT) to evaluate the pore network architecture of sidewall cores recovered 2 years after CO2 injection. In this study, we performed a detailed quantitative analysis of the CO2-reacted basalt cores by XMT imaging. Reconstructed 3D images were analyzed to determine the distribution and volumetric details of porosity and anthropogenic carbonate nodules in the cores. Additional mineralogic quantification provided insight into the overall paragenesis and carbonate growth mechanisms, including mineralogic/chemical zonation. These findings are being used to parametrize multiphase reactive transport models to predict the fate and transport of subsurface CO2, enabling scale-up to commercial-scale geologic carbon storage in basalts and other reactive mafic-ultramafic formations.


Assuntos
Dióxido de Carbono , Carbono , Silicatos , Microtomografia por Raio-X , Dióxido de Carbono/química , Projetos Piloto , Carbonatos
4.
J Synchrotron Radiat ; 31(Pt 2): 363-377, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38386565

RESUMO

The ForMAX beamline at the MAX IV Laboratory provides multiscale and multimodal structural characterization of hierarchical materials in the nanometre to millimetre range by combining small- and wide-angle X-ray scattering with full-field microtomography. The modular design of the beamline is optimized for easy switching between different experimental modalities. The beamline has a special focus on the development of novel fibrous materials from forest resources, but it is also well suited for studies within, for example, food science and biomedical research.

6.
J Dent Res ; 103(1): 22-30, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38058155

RESUMO

Amelogenesis imperfecta (AI) comprises a group of rare, inherited disorders with abnormal enamel formation. Ameloblastin (AMBN), the second most abundant enamel matrix protein (EMP), plays a critical role in amelogenesis. Pathogenic biallelic loss-of-function AMBN variants are known to cause recessive hypoplastic AI. A report of a family with dominant hypoplastic AI attributed to AMBN missense change p.Pro357Ser, together with data from animal models, suggests that the consequences of AMBN variants in human AI remain incompletely characterized. Here we describe 5 new pathogenic AMBN variants in 11 individuals with AI. These fall within 3 groups by phenotype. Group 1, consisting of 6 families biallelic for combinations of 4 different variants, have yellow hypoplastic AI with poor-quality enamel, consistent with previous reports. Group 2, with 2 families, appears monoallelic for a variant shared with group 1 and has hypomaturation AI of near-normal enamel volume with pitting. Group 3 includes 3 families, all monoallelic for a fifth variant, which are affected by white hypoplastic AI with a thin intact enamel layer. Three variants, c.209C>G; p.(Ser70*) (groups 1 and 2), c.295T>C; p.(Tyr99His) (group 1), and c.76G>A; p.(Ala26Thr) (group 3) were identified in multiple families. Long-read AMBN locus sequencing revealed these variants are on the same conserved haplotype, implying they originate from a common ancestor. Data presented therefore provide further support for possible dominant as well as recessive inheritance for AMBN-related AI and for multiple contrasting phenotypes. In conclusion, our findings suggest pathogenic AMBN variants have a more complex impact on human AI than previously reported.


Assuntos
Amelogênese Imperfeita , Proteínas do Esmalte Dentário , Animais , Humanos , Amelogênese/genética , Amelogênese Imperfeita/genética , Proteínas do Esmalte Dentário/genética , Proteínas do Esmalte Dentário/metabolismo , Linhagem , Fenótipo
7.
J Plant Res ; 137(1): 79-94, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37812342

RESUMO

In the Malvaceae family, dynamic solar tracking by leaves is actuated by the deformation of the pulvinus, a thickened region at the leaf blade-petiole junction. While the internal structure is believed to play a crucial role in this process, experimental verification has been challenging due to technical limitations. To address this gap, we developed a semi-automated workflow, which integrates data analysis and image processing to simultaneously analyze the shape and internal structure of a Malvaceae pulvinus using X-ray microtomography. Firstly, we found that kenaf (Hibiscus cannabinus L.), a Malvaceae species with curved pulvini, exhibited solar-tracking leaf movement and selected it as a model system. We employed diffusible iodine-based contrast-enhanced computed tomography to visualize the internal structure of the kenaf pulvinus. Analysis of the pulvini's shape revealed variations in pulvinus morphology, yet plausible prediction of the centerline was accomplished using polar polynomial regression. Upon slicing the pulvini perpendicular to the centerline, we observed distinct gray value gradients along the proximo-distal and adaxial-abaxial axes, challenging threshold-based tissue segmentation. This workflow successfully generated three modified 3D images and derived quantitative parameters. Using these quantitative parameters, we conducted network analysis and found the linkage between the size-normalized cortex cross-sectional area and curvature. Polynomial least absolute shrinkage and selection operator (LASSO) regression revealed the relationship between the size-normalized cortex cross-sectional area and curvature commonly in all three tested samples. This workflow enables simultaneous analysis of the shape and internal structure, significantly improving the reproducibility of Malvaceae leaf pulvinus characterization.


Assuntos
Hibiscus , Pulvínulo , Microtomografia por Raio-X , Reprodutibilidade dos Testes , Folhas de Planta
8.
Braz. oral res. (Online) ; 38: e006, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1528151

RESUMO

Abstract The aim of this study was to evaluate the root canal shaping effect of ProTaper Gold (PTG) versus ProTaper Next (PTN) instrumentation systems, and of a manual #15 K-type file (K15) versus the ProGlider (PG) mechanized instrument for glide path creation, in severely curved mesial canals. Twenty-four mandibular molars with two separate mesial canals were anatomically matched using computed tomographic scanning, and then divided into two groups (n=12) according to the glide path instrument used, either K15 or PG. In all teeth, the PTG system was used to prepare the mesiobuccal canal, and the PTN, the mesiolingual canal. The teeth were scanned by computed microtomography, before and after root canal preparation, and the values of the initial volume, final volume, volumetric variation, untouched walls, and canal transportation variables were determined. The data were analyzed using the two-way ANOVA test, and the Tukey test for multiple comparisons. There was no significant difference among the study groups regarding volumetric variation or root canal transportation, either in the cervical, middle or apical thirds, or in the entire root canal (p>0.05). In the apical third, the percentage of untouched walls was significantly higher in groups using K15 than in those using PG (p<0.05), namely 33.144% and 23.285%, respectively, irrespective of the instrumentation system. In the other regions, there was no difference between K15 and PG regarding this variable. It was concluded that PG was associated with a lower rate of untouched walls in the apical region than K15.

9.
Braz. dent. j ; 35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1550089

RESUMO

Abstract: The aim was to evaluate primary implant stability and bone microarchitecture in two drilling situations, by comparing the conventional technique (CT) and osseodensification (OD) (Versah Burs - Jackson - Mississippi - USA). The implant insertion torque (IT), implant stability quotient (ISQ), and the peri-implant trabecular microstructure were assessed on bone fragments obtained from pig's tibia (n=12), divided between CT (n=6) and OD (n=6). After the drilling procedure, the implants were installed (3.5x8.5 mm, Epikut - SIN - São Paulo - Brazil). The IT and ISQ were measured using a digital torque wrench and resonance frequency analysis. Then, the bone fragments containing the implants were removed with a trephine and analyzed by Microtomography (µCT, 8.0 µm). The comparison between groups was performed using the unpaired t-test (α=0.05). The results revealed that OD promotes a higher insertion torque (CT: 7.67±2.44 Ncm; OD: 19.78±5.26 Ncm) (p=0.0005), although ISQ was not different (CT: 61.33±4.66; OD: 63.25±4.58) (p=0.48). There was a significant increase in peri-implant bone volume (CT: 23.17±3.39 mm3; OD: 32.01±5.75 mm3) (p=0.008), and trabecular parameters: separation (CT: 0.4357±0.03 mm; OD: 0.3865±0.04 mm) (p=0.0449), number (CT: 1.626±0.18 1/mm; OD: 1.946±0.13 1/mm) (p=0.007), and thickness (CT: 0.1130±0.009 mm; OD: 0.1328±0.015 mm) (p=0.02). Structure model index (SMI) data demonstrate no significant differences between groups (CT: 1.7±0.2; OD: 1.4±0.4) (p=0.12). In conclusion, OD increases the insertion torque values and promotes beneficial changes regarding bone microarchitecture compared with CT, revealing more peri-implant bone volume with consequent higher primary stability.


Resumo O objetivo deste estudo foi avaliar a estabilidade de implante e a microarquitetura óssea em duas técnicas de fresagem, comparando a técnica convencional (CT) e a osseodensificação (OD) (Versah Burs - Jackson - Mississippi - EUA). O torque de inserção do implante (IT), quociente de estabilidade primária (ISQ) e a estrutura trabecular peri-implantar foram avaliados em fragmentos ósseos obtidos de tíbia de porco (n=12), divididos entre CT (n=6) e OD (n=6). Após o procedimento de fresagem, foram instalados implantes (3,5x8,5 mm, Epikut - SIN - São Paulo - Brasil). O IT e o ISQ foram aferidos por meio de um torquimetro digital e análise de frequência de ressonância. Em seguida, os fragmentos ósseos contendo os implantes foram removidos com trefina e analisados ​​por microtomografia computadorizada (µCT, 8,0 µm). A comparação entre os grupos foi realizada por meio do teste-t não-pareado (α=0.05). Os resultados revelaram que a OD promove maior torque de inserção (CT: 7,67 ± 2,44º Ncm; OD: 19,78 ± 5,26 Ncm) (p=0,0005), embora a estabilidade primária não tenha sido diferente (CT: 61.33 ± 4.66; OD:63.25 ± 4.58) (p=0,48). Houve um aumento significativo no volume ósseo peri-implantar (CT: 23,17±3,39 mm3; OD: 32,01±5,75 mm3) (p=0,0089) e parâmetros trabeculares: separação (CT: 0,4357 ± 0,03 mm; OD: 0,3865 ± 0,04 mm) (p=0,0449), número (CT: 1,626 ± 0,18 1/mm; OD: 1,946 ± 0,13 1/mm) (p=0,007) e espessura (CT: 0,1130 ± 0,009 mm; OD: 0,1328 ± 0,015 mm) (p=0,02) O índice de modelo estrutural (SMI) não demostrou diferença estatisticamente significativa (p=0.1228). Concluindo, OD apresenta maiores valores de torque de inserção e promove mudanças benéficas na microarquitetura óssea em comparação com a TC, revelando maior volume ósseo peri-implantar.

10.
J Synchrotron Radiat ; 31(Pt 1): 150-161, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38117694

RESUMO

Third- and fourth-generation synchrotron light sources with high fluxes and beam energies enable the use of innovative X-ray translucent experimental apparatus. These experimental devices access geologically relevant conditions whilst enabling in situ characterization using the spatial and temporal resolutions accessible at imaging beamlines. Here, Heitt Mjölnir is introduced, a heated miniature triaxial rig based on the design of Mjölnir, but covering a wider temperature range and larger sample volume at similar pressure capacities. This device is designed to investigate coupled thermal, chemical, hydraulic and mechanical processes from grain to centimetre scales using cylindrical samples of 10 mm × 20 mm (diameter × length). Heitt Mjölnir can simultaneously reach confining (hydraulic) pressures of 30 MPa and 500 MPa of axial stress with independently controlled sample pore fluid pressure < 30 MPa. This internally heated apparatus operates to temperatures up to 573 K with a minimal vertical thermal gradient in the sample of <0.3 K mm-1. This new apparatus has been deployed in operando studies at the TOMCAT (Swiss Light Source), I12 JEEP (Diamond Light Source) and PSICHÉ (Synchrotron SOLEIL) beamlines for 4D X-ray microtomography with scan intervals of a few minutes. Heitt Mjölnir is portable and modular, allowing a wide range of 4D characterizations of low-grade metamorphism and deformational processes. It enables spatially and temporally resolved fluid-rock interaction studies at conditions of crustal reservoirs and is suitable for characterization of material properties in geothermal, carbonation or subsurface gas storage applications. Technical drawings and an operation guide are included in this publication.

11.
Eur Radiol Exp ; 7(1): 76, 2023 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-38049615

RESUMO

BACKGROUND: Diagnostic accuracy of endomyocardial biopsy could improve if clinically safe magnetic resonance (MR)-compatible bioptomes were available. We explored two novel MR-compatible cardiac bioptomes for performance, safety, and clinical viability, employing in vivo minipig trials and phase-contrast synchrotron radiation computed microtomography (SRµCT). METHODS: Analysis of ex vivo obtained pig endomyocardial biopsies was performed using phase-contrast SRµCT and conventional two-dimensional histology. The technical performance was evaluated by measuring volume, inner and outer integrities, compression, and histological diagnostic value in 3 sets (6 per set) of biopsies for each experimental bioptome. The bioptomes were tested in vivo in 3 healthy minipigs per bioptome. The clinical feasibility was evaluated by procedural and cutting success as well as histological diagnostic value. RESULTS: The bioptome with the 'grind-grind' design achieved similar values to control in compression (p = 0.822), inner (p = 0.628), and outer (p = 0.507), integrities ex vivo. It showed a better performance in the in vivo real-time MRI setting demonstrating a higher cutting success (91.7%) than the 'grind-anvil' (86.2%) design. In both ex vivo and in vivo evaluations, the 'grind-grind' design displayed sufficient diagnostic value (83% and 95%). The 'grind-anvil' design showed adequate diagnostic value both ex vivo and in vivo (78% and 87.5%) but was not comparable to control according to the three-dimensional (3D) analysis. CONCLUSION: A novel MR-compatible bioptome was identified as plausible in a clinical setting. Additionally, SRµCT and subsequent 3D structural analysis could be valuable in the label-free investigation of myocardial tissue at a micrometer level. RELEVANCE STATEMENT: Implementation of MR-guided biopsy can improve animal studies on structural myocardial changes at any point in an experimental setup. With further improvements in guiding catheters, MR-guided biopsy, using the new bioptome, has a potential to increase quality and diagnostic accuracy in patients both with structural and inflammatory cardiomyopathies. KEY POINTS: • Novel MR-compatible bioptomes show promise for a clinical application. • SRµCT enabled detailed analysis of endomyocardial biopsies. • The bioptomes showed adequate in vivo performance without major complications.


Assuntos
Coração , Imageamento por Ressonância Magnética , Animais , Humanos , Suínos , Porco Miniatura , Coração/diagnóstico por imagem , Biópsia/métodos , Espectroscopia de Ressonância Magnética
12.
Odovtos (En línea) ; 25(3): 32-42, Sep.-Dec. 2023. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia, SaludCR | ID: biblio-1529067

RESUMO

Abstract The aim of this study was to compare the filling capacity in curved root canal using a new continuous wave of condensation technique (Termo Pack II, Easy Dental Equipments, Brazil) or lateral compaction. The percentage of voids in the filling of mesial root canals of mandibular molars was assessed by micro-computed tomography (micro-CT). Mesial root canals (n=24) of mandibular molars with a degree of curvature between 20° and 40° were prepared using rotary system (ProDesign Logic, Easy, Brazil) up to #35, .05 taper. The root canals were filled by using the continuous wave of condensation system or lateral compaction and AH Plus sealer (n=12). Scanning at 9 µm was performed after preparation and after filling by using micro-CT SkyScan 1176. The volumetric percentage of filling material and voids (total length and in each root canal third) were calculated. Data were analyzed using ANOVA/ Tukey and Student's t tests (α=0.05). Before the filling techniques, the root canals volume after preparation was similar (p>0.05). The root canals filled by the continuous wave of condensation technique presented the lowest percentage of voids, and the greatest percentage of filling material in total length and thirds (cervical, middle and apical) (p<0.05). Both techniques were not able of completely filling the root canals. The continuous wave of condensation technique Termo Pack II promoted better root canal filling in curved root canals, when compared with lateral compaction.


Resumen El objetivo de este estudio fue comparar la capacidad de obturación en conductos radiculares curvos utilizando una nueva técnica de condensación de onda continua (Termo Pack II, Easy Dental Equipments, Brasil) vs compactación lateral. El porcentaje de brechas en la obturación de los conductos radiculares mesiales de los molares mandibulares se evaluó mediante microtomografía computarizada (micro-CT). Se prepararon conductos radiculares mesiales (n=24) de molares mandibulares con un grado de curvatura entre 20° y 40° utilizando un sistema rotatorio (ProDesign Logic, Easy, Brasil) al #35, conicidad 0,05. Los conductos radiculares se obturaron utilizando un sistema de condensación de onda contínua o compactación lateral y cemento AH Plus (n=12). Se realizó un escaneo de 9 µm después de la preparación y después de la obturación usando el micro-CT SkyScan 1176. Se calculó el porcentaje volumétrico de material de obturación y vacíos (longitud total y en cada tercio del conducto radicular). Los datos se analizaron utilizando las pruebas ANOVA/Tukey y t de Student (α=0,05). Antes de las técnicas de obturación, el volumen de los conductos radiculares después de la preparación fue similar (p>0,05). Los conductos radiculares obturados con la técnica de condensación por onda contínua presentaron el menor porcentaje de vacíos y el mayor porcentaje de material de obturación en longitud total y en tercios (cervical, medio y apical) (p<0,05). Ambas técnicas no fueron capaces de llenar completamente los conductos radiculares. La técnica de condensación de onda contínua Termo Pack II promovió un mejor relleno del conducto radicular en conductos radiculares curvos en comparación con la compactación lateral.


Assuntos
Obturação do Canal Radicular/instrumentação , Condensação , Polpa Dentária , Microtomografia por Raio-X/instrumentação
13.
Biology (Basel) ; 12(12)2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38132298

RESUMO

Unicellular protozoa form calcium carbonate tests. It is important to understand the features and mechanisms of its formation. This may shed light on the processes of shell formation in metazoans. One of the most important characteristics of the Protozoa carbonate test is the degree of crystal ordering that can be described by crystallographic texture. The crystallographic texture data of calcite in the foraminifera Nummulites distans (Deshayes) test from the Eocene deposits (Cenozoic, Paleogene) of the Crimea Peninsula are obtained using X-ray diffraction. A very strict orientation of the crystals is revealed. The calcite texture sharpness is several times greater than in the shells of the bivalve mollusk Placuna placenta (Linnaeus), measured by the same method. It also exceeds the crystallographic texture and sharpness of the same mineral in the shells of the bivalves of Mytilus galloprovincialis (Lamarck), studied by neutron diffraction. It is concluded that a high level of control during test formation is already characteristic of protozoa. Studying the processes involved in the formation of a very sharp crystallographic texture can become an important direction for creating nature-like materials with desired properties.

14.
Acta odontol. latinoam ; 36(3): 163-168, Dec. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1533522

RESUMO

ABSTRACT Root canal morphology and its anatomical variations pose a great challenge to endodontists Aim The aim of this in silico study was to perform a qualitative and quantitative analysis of the threedimensional morphological characteristics of the isthmus in the mesial root canals of mandibular molars using microcomputed tomography (micro-CT) Material and Method Six hundred first mandibular molars were selected, including 317 with two mesial canals with isthmuses between the canals, and fully formed root. Isthmus morphology was determined in 3D longitudinal sections using Fan et al. (2010) classification. Root length, and the volume and area of apical and coronal level were measured. Additionally, the structural model index (SMI) of the canals were also assessed Results The prevalence of isthmuses in the mesial root canals was 32% type II, 29% type III, 22% type IV, and 17% type I. The root length was found to be 9.1±0.5 mm, the volume and area, of all root canal system, were 41.8±40.1 mm3 and 63.6±24.2 mm2 respectively. The isthmi volume and area alone were 11.06±9.03 mm3 and 30.02±11.02 mm2. The study confirmed that isthmuses are present in mesial canals of mandibular first molars, being more frequent in the apical third Conclusion The high prevalence of isthmuses with complex morphological features underscores the importance of using intracanal medications to disinfect areas unprepared by instruments.


RESUMO A morfologia do canal radicular e suas variações anatômicas representam um grande desafio para os endodontistas. O objetivo deste estudo ex vivo foi realizar uma análise qualitativa e quantitativa das características morfológicas tridimensionais do istmo nos canais mesiais de molares inferiores por meio de microtomografia computadorizada (micro-CT) Material e Método Foram selecionados 600 primeiros molares inferiores, incluindo 317 com dois canais mesiais com istmos e raiz totalmente formada. A morfologia do istmo foi determinada em cortes longitudinais 3D usando a classificação Fan et al. (2010). Foram mensurados o comprimento da raiz, o volume e a área apical e coronal e da cavidade pulpar. Adicionalmente, também foram avaliados o structure model index (SMI) dos canais Resultados A prevalência de istmos nos canais mesiais foi de 32% tipo II, 29% tipo III, 22% tipo IV e 17% tipo I. O comprimento da raiz foi de 9,1±0,5 mm, o volume e a área de todo o sistema de canais radiculares foram de 41.8±40.1 mm3 e 63.6±24.2 mm2, respectivamente. O volume e área do istmo isoladamente foram 11.06±9,03 mm3 e 30.02±11.02 mm2. O estudo confirmou que os istmos estão presentes em canais mesiais dos primeiros molares inferiores, sendo mais frequentes no terço apical Conclusão A alta prevalência de istmos com características morfológicas complexas ressalta a importância do uso de medicação intracanal para desinfecção de áreas não tocadas por instrumentos.

15.
Acta odontol. latinoam ; 36(3): 177-182, Dec. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1533524

RESUMO

ABSTRACT Current instrumentation systems cannot fully prepare oval root canal systems. This may cause accumulation of hard tissue debris and fail to eliminate bacteria from areas inaccessible to instrumentation, which could perpetuate periapical inflammation and jeopardize the success of endodontic treatment Aim To evaluate the performance of two endodontic systems in oval canals by investigating the changes in volume, unprepared areas, and centering ability of XP-endo Shaper (XPS) and WaveOne Gold (WOG) in oval canals using microcomputed tomography (micro-CT) Materials and Method Thirty mandibular canines were scanned before and after preparation with WOG (25/.07 and 35/.06) or XPS (30/.01) to evaluate the volume, surface area, and canal centralization at 4 mm and 10 mm from the apical foramen Results Volume and surface area increased significantly after preparation with both systems (p<0.05). However, no significant difference was observed in the unprepared areas, regarding either the entire canal (26.21% for WOG and 30.10% for XPS), or the apical segment (18.82% for WOG and 14.63% for XPS) (p >0.05) Conclusions Both systems maintained canal centralization, with no difference between them. XPS and WOG had similar shaping abilities in the mandibular canine, but left almost one third of the unprepared areas.


RESUMO Os sistemas de instrumentação atuais são incapazes de preparar completamente os sistemas de canais radiculares do canal oval, o que pode levar ao acúmulo de detritos de tecido duro e manter micro-organismos em áreas inacessíveis à instrumentação. Essas bactérias poderiam perpetuar a inflamação periapical e comprometer o sucesso do tratamento endodôntico Objetivo Para avaliar o comportamento de dois sistemas endodônticos em canais ovais, esse estudo investigou as alterações no volume, áreas não preparadas e capacidade de centralização do XP-endo Shaper (XPS) e do WaveOne Gold (WOG) em canais ovais usando microtomografia computadorizada (micro-CT) Material e métodos Trinta caninos inferiores foram escaneados antes e depois do preparo com WOG (25/.07 e 35/.06) ou XPS (30/.01) para avaliar o volume, a área de superfície e a centralização do canal a 4 mm e 10 mm do forame apical Resultados O volume e a área de superfície aumentaram significativamente após o preparo com ambos os sistemas (p<0,05). No entanto, não foram observadas diferenças significativas nas áreas não preparadas, não apenas em todo o canal (26,21% para WOG e 30,10% para XPS), mas também no segmento apical (18,82% para WOG e 14,63% para XPS) (p >0,05) Conclusão Ambos os sistemas mantiveram a centralização do canal, sem diferenças entre eles. O XPS e o WOG tiveram habilidades de modelagem semelhantes no canino mandibular, mas deixaram quase um terço das áreas do canal sem preparo.

16.
Int J Paediatr Dent ; 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-37994194

RESUMO

BACKGROUND: Eccentric instruments have been proposed as more effective and less time-consuming for endodontic instrumentation. AIM: To compare biomechanical outcomes of different instrumentation systems and time undertaken for instrumentation in resin prototypes. DESIGN: Sixty standardized prototypes of mandibular second primary molars were instrumented according to the following systems: K-files, ProTaper Next (PTN), XP-endo Shaper (XPS), XP-endo Finisher (XPF), XP-Clean (XPC), and Sequence Baby File (SBF; n = 10/each). Irrigation was performed with saline with simultaneous aspiration, and time spent was recorded. The prototypes were micro-CT-scanned before and after the instrumentation, and image sets were reconstructed and registered. Non-instrumented areas, accumulated debris, removed root material volume, and canal transportation were quantified. Data were analyzed through ANOVA, the Kruskal-Wallis test, and the Wilcoxon signed-rank test (α = 5%). RESULTS: K-files and SBF resulted in more instrumentation time (p < .05). SBF, XPC and PTN removed less root dentine (p < .05), but PTN left more untouched areas (p < .05). Accumulated debris were lower for XPC and SBF (p < .05). Canal transportation was similar among the groups. CONCLUSION: Rotary systems reduced instrumentation time, whereas SBF and XPC resulted in more conservative instrumentation, with less debris accumulation and non-instrumented areas. A dedicated paediatric endodontic system (SBF) outperformed eccentric instruments in terms of effectiveness.

17.
Front Plant Sci ; 14: 1256772, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37954987

RESUMO

Bamboo is a natural vascular bundle (VB) reinforced composite material used in more than 10 fields such as construction and furniture. The nodes in bamboo are crucial to its mechanical properties, but understanding of its performance is limited by lack of knowledge about the three-dimensional (3D) structure of the node. This work aimed to non-destructively identify the multi-dimensional characteristics of the VB in a bamboo branched node (BN) using X-ray microtomography (µCT). The VB was segmented from the BN using deep learning combined with the Watershed algorithm. The 3D model reconstruction and characterization of the VB were also conducted. It was found that the structure of VBs showed significant changes along the height of the BN. The VBs formed a complex 3D structure, VBs of the culm are connected with those of the branch, and the connectivity of the conducting tissue and fibers was 88.91% and 99.95%, respectively. The conducting tissue and the fibers had similar shapes but varying thicknesses, which enabled VBs to perform both water transport and mechanical support functions. The volumes fraction of parenchyma, fibers, and conducting tissue in the BN were 61.3%, 35.3%, and 3.4%, respectively, but the tissue proportion of the different heights of the BN varied from each other. The nodal ridge was a mechanical weak point of the BN, with a maximum fibers proportion of 43.8%. This study contributes to understanding the relationship of VBs between the branch and the culm. It provides a structural perspective for understanding the mechanical properties of BN and a theoretical basis for optimizing bamboo utilization efficiency.

18.
Radiat Environ Biophys ; 62(4): 511-518, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37792108

RESUMO

The objectives of the present study were to assess Fractal Dimension (FD) values in the mandible cortical bone obtained from digital periapical radiographs (DPR), high-resolution microtomography (µCT), and cone-beam computed tomography (CBCT), by two processing methods: binarization (FD.b) and grayscale-based method (FD.f) and, finally, to identify the correlation among these values with other micro-architectural parameters. For this, a prospective study was conducted on 18 healthy individuals (mean age 23 ± 2.4 years old) who underwent third molar extraction. Pre-operative CBCT scans were conducted, bone fragments were removed from the retro-molar region, and DPR and µCT were performed on those bone samples. FD.b and FD.f values were calculated using three parasagittal sections for CBCT, one image for DPR, and three sections for µCT. The 3D bone microarchitecture was analyzed in µCT (voxel size: 19 µm). As a result, FD.b mean values of 1.55 ± 0.02 and 1.80 ± 0.01 were obtained for CBCT and µCT, respectively. Furthermore, FD.f mean values of 1.22 ± 0.12 for DPR, 0.99 ± 0.04 for CBCT, and 1.30 ± 0.07 for µCT were obtained. Both FD.b and FD.f values showed a good agreement. FD.f was negatively correlated with the standard deviation of the mean gray value (p = 0.003) for DPR and intra-cortical bone surface (p = 0.02) for µCT. In conclusion, image processing with or without binarization revealed different values for FD, although showing agreement. The grayscale-based method retrieved FD values correlated with the gray levels and the cortical porous network, which means that FD can be a valuable index for mandibular cortical bone evaluation. FD is associated with mineralization and microarchitecture. Nevertheless, there was no correlation between FD values obtained from low- (DPR) and high-resolution (µCT) X-ray modalities with FD obtained from the in vivo CBCT.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Fractais , Humanos , Adulto Jovem , Adulto , Microtomografia por Raio-X/métodos , Estudos Prospectivos , Osso Cortical , Mandíbula
19.
Diagnostics (Basel) ; 13(20)2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37892078

RESUMO

This in vitro study aimed to investigate the diagnostic potential of short-wave infrared transillumination (SWIRT) at 1050, 1200 and 1300 nm for the detection of proximal caries in molars and premolars. It was compared to the diagnostic performance of bitewing radiography (BWR) and micro-computed tomography (µCT) as the reference standard. 250 sound or decayed proximal surfaces of permanent posterior extracted teeth were examined using (1) SWIRT at 1050, 1200 and 1300 nm with two camera systems of different resolutions, (2) BWR and (3) µCT. Thresholds were defined for both test methods and the reference standard for caries in general, enamel caries and dentin caries. All images were assessed by two examiners twice, at an interval of two weeks. SWIRT at wavelengths of 1050, 1200 and 1300 nm achieved sensitivity values more than 2.5 times higher than BWR (enamel caries 3.2-4.4 times; dentin caries 3.25-4.25 times) for the detection of proximal caries. Sensitivity values of SWIRT improved with the higher wavelength. No significant difference was found in diagnostic quality between the two camera systems. SWIRT at 1300 nm imaged proximal enamel caries with the highest accuracy, while the physical optimum for transillumination in dentin was located at a lower wavelength (<1000 nm).

20.
Front Neurosci ; 17: 1236876, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37869518

RESUMO

Corpora amylacea (CA) are polyglucosan aggregated granules that accumulate in the human body throughout aging. In the cerebrum, CA have been found in proximity to ventricular walls, pial surfaces, and blood vessels. However, studies showing their three-dimensional spatial distribution are sparse. In this study, volumetric images of four human brain stems were obtained with MRI and phase-contrast X-ray microtomography, followed up by Periodic acid Schiff stain for validation. CA appeared as hyperintense spheroid structures with diameters up to 30 µm. An automatic pipeline was developed to segment the CA, and the spatial distribution of over 200,000 individual corpora amylacea could be investigated. A threefold-or higher-density of CA was detected in the dorsomedial column of the periaqueductal gray (860-4,200 CA count/mm3) than in the superior colliculus (150-340 CA count/mm3). We estimated that about 2% of the CA were located in the immediate vicinity of the vessels or in the peri-vascular space. While CA in the ependymal lining of the cerebral aqueduct was rare, the sub-pial tissue of the anterior and posterior midbrain contained several CA. In the sample with the highest CA density, quantitative maps obtained with MRI revealed high R2* values and a diamagnetic shift in a region which spatially coincided with the CA dense region.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...